Tri-proof Light Dimmable Sensor, Long Strip Shell, Miniature Antenna Design, No Shading
| Lugar de origen | Shénzhen, China |
|---|---|
| Nombre de la marca | Merrytek |
| Certificación | CE |
| Número de modelo | MC137D C y MC137D D |
| Cantidad de orden mínima | 100 piezas |
| Precio | Negociable |
| Detalles de empaquetado | Bolsa de burbujas + tabique + caja exterior (K=A) |
| Tiempo de entrega | 1, muestra y pedido pequeño: dentro de los 5 días hábiles posteriores a la recepción del pago. 2, pe |
| Condiciones de pago | T/T |
| Capacidad de la fuente | 10000 unidades/mes |
Póngase en contacto conmigo para muestras y cupones gratis.
WhatsApp:0086 18588475571
- ¿ Qué es eso?: 0086 18588475571
¿ Qué pasa?: sales10@aixton.com
Si usted tiene alguna preocupación, proporcionamos ayuda en línea de 24 horas.
xDatos del producto
| Tensión nominal | 12 ± 1 VCC | Voltaje de ondulación | Se aplicará el método siguiente: |
|---|---|---|---|
| Frecuencia de trabajo | 5.8GHz ±75MHz, banda ISM | Altura de instalación | 3 m (5 m máximo) |
| Temperatura de trabajo | Construido en: -25 ~ 60 °C | Vida | Garantía de 5 años@TA |
| Resaltar | dimmable motion sensor tri-proof light,long strip shell tri-proof light,miniature antenna sensor light |
||
Descripción de producto
Tri-proof Light Dimmable Sensor with Miniature Antenna Design
Product Features
- Patented Mini Coupling Dipole Antenna
- Long strip shell with miniature antenna design, eliminating shading issues
- Ultra-low RF power output, safe for human health
- Remote control and DIP switch for adjusting sensing parameters
- Low side lobe with high adaptability to metal environments
- Unaffected by temperature, humidity, noise, airflow, dust, and light conditions
Technical Parameters
| Input Specifications | |
|---|---|
| Rated Voltage | 12 ± 1VDC |
| Working Current | MC137D C: 20±2mA | MC137D D: 16±2mA |
| Ripple Voltage | < 100mVp-p |
| Output Specifications | |
| Output Signal | MC137D C: 0-10VDC dimming signal | MC137D D: PWM dimming signal |
| Daylight Sensor | |
| Daylight Sensor | Daylight priority |
| Sensing Parameters | |
| Working Frequency | 5.8GHz ±75MHz, ISM band |
| Transmit Power | 1mW Max. |
| Detection Range (Radius) | Ceiling installation 3m high: r≥4m@0.3m/s, r≥2.5m@1m/s Horizontal installation 2m high: r≥8m@0.3m/s, r≥4m@1m/s |
| Installation Height | 3m (5m Max) |
| Environmental Specifications | |
| Working Temperature | Built-in: -25~60℃ |
| Storage Temperature | -40℃…80℃, humidity ≤85% (non-condensing) |
| Certification Standards | |
| Certified | CE, RED (Pending) |
| Environmental Requirements | Complies with RoHS 2.0, Reach requirements |
| IP Rating | IP20 |
| Other Specifications | |
| Wiring | 3pin 2.0mm terminal |
| Installation Requirements | Built-in installation |
| Packaging Requirements | Bubble bag + partition + outer box (K=A) |
| Net Weight | 10±2g |
| Lifetime | 5 Years Warranty |
Model Selection
| MC137D C | MC137D D |
|---|---|
| 0-10VDC dimming signal | PWM dimming signal |
| Daylight priority | |
Function Description
| Function | MC137D C, MC137D D |
|---|---|
| ON/OFF Function | N/A |
| Two-step Dimming Function | N/A |
| Three-step Dimming Function | Stand-by Period be set to "5min/10min/30min" |
| Daylight Harvesting | N/A |
| Daylight Priority | Stand-by Period be set to "+∞" |
Technical Diagrams
Recommended for use on ceiling lights
Dimensions
Wiring Diagram & Function Diagram
Installation Diagram
Installation Notice: When installing, please pay attention to the distance between the microwave antenna and the light board.
DIP Switch Settings
| Function | Detection Area | Hold Time | Daylight Sensor | Stand-by Dim Level | Stand-by Period | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dial Code | 1 | 2 | 3 | 4 | 5 | 6 | |||||||
| Ⅰ | - | 100% | - | - | 5s | - | Disable | 5Lux/15Lux/30Lux/50Lux | 100-150Lux | - | 0% | - | +∞ |
| Ⅱ | ON | 50% | - | ON | 1min | ON | 30Lux | 100Lux | 200Lux | ON | 20% | ON | 15min |
| Ⅲ | ON | - | 3min | 150Lux | 300Lux | ||||||||
| Ⅳ | ON | ON | 10min |
Remote Control Instructions
Initialization: The sensor will turn on the light at 100% brightness for the first time, and turn it off after 10 seconds. During the initialization period, sensor is not able to detect movement.
Default Setting: Sensitivity: 100% | Hold time: 5s | Daylight Sensor: Disable | Stand-by period: 15min | Stand-by Dim Level: 0%
Application Guidelines
- The sensor should be installed by a professional electrician. Please cut off the power before installing, wiring, changing the setting of the dial switch, etc.
- The sensing distance is related to factors such as the moving speed of the moving object, the size of the moving object, the installation height, the installation angle, whether the installation environment is open, and the material of the reflector.
- When the microwave sensor is installed on the wall, the detection distance will be greatly increased compared with that installed on the ceiling. If you use the wall installation method, please reduce the sensitivity to use or contact our company to confirm the use setting.
- Sensor parameters may need to be reconfigured in different installation environments.
- This sensor is only for indoor use, outdoor wind and rain, and surrounding moving objects will cause false triggering.
- The installation height of the sensor product cannot exceed 6 meters, and the optimal height is 3 meters; the distance between the two sensors should be greater than 3 meters.
- When the sensor is installed in a metal lamp, on a metal reflective surface, or in a narrow closed environment, microwaves will be reflected multiple times and cause false triggering.
- Please make sure that there are no moving signals such as fans, DC motors, sewer pipes, air outlets, etc. around the sensor.
- Microwaves cannot penetrate metal, avoid installing in closed or semi-closed metal lamps, and there should be no metal or glass blocking the product.
- A DC regulated power supply with stable output voltage and low ripple coefficient must be used. The ripple of the power supply should be less than 100mV; the load current should be greater than 25mA.
- Product specifications and parameters may be optimized without prior notice.
Productos recomendados